All
of the Golden Grain model stoves
are equipped with an automatic
shut down cycle. The shut down
cycle is initiated if the fire
should go out or if the stove
overheats. All models have
positive exhaust systems
allowing them to be vented
horizontally through an outside
wall. A large circulating blower
to maximize heat output turns on
automatically only when there is
heated air to circulate. Out
auger feed system is designed to
allow cob pieces and spikes up
to 1" in size to pass through
without jamming. Window air wash
systems help keep the Ceramic
Glass viewing windows clean. All
stoves have built-in wipers and
clean-outs, which make it easy
to maintain high efficiency for
years of quality service.
|
|
 |
Model 1201
Fireplace Insert
Dimensions: 24" wide X 24"
deep X 22" tall,
Extending 10" out of
fireplace
Hopper Capacity: 40 lbs
Minimum Clearance:
Side to Wall: 4"
Back to Wall: 1"
Weight: 228 lbs.
Shipping Weight: 248 lbs.
Room Blower: 265 cfm
Exhaust Blower: 216 cfm
Fuel: Whole Kernel Corn,
Wheat, Barley
and/or Wood Pellets
Air Intake Pipe outside
diameter: 2 in. OD
Flue Size: 3 in. metal flex
up passed the smoke shelf
BTU Input Range: (Corn)
14,000 to 40,000
Feed Rate: 1.5 lbs./hr. low
to 4.4 lbs./hr. maximum
Power Required: 120 Volts,
400 Watts or 3 Amps |
|
|
back to top |
Model 1201 Fireplace Insert
Features:
-
Model 1201 fireplace insert
Easy front / top loading hopper.
Ornately designed - combining
artistry and technology.
-
Large
heat exchanger with built in
cleaning system
-
Unique auger feed design - no
jamming
-
Visible Flame
-
Full
range of heat settings -
13,000 to 40,000 BTU
-
Multi fuel - Corn, Wheat,
Barley, Rye, and/or Wood pellets
-
Can also
be mounted on legs or a pedestal as
a free standing unit
|
|
 |
Model
3101 Portable Large Commercial
Dimensions: 24" wide X 43" deep
X 36" tall,
Hopper Capacity: 40 lbs,
Secondary Hopper - 200 lbs.
Minimum Clearance:
Side to Wall: 23"
Back to Wall: 16"
Weight: 419 lbs. with standard
Secondary Hopper
Shipping Weight: 480 lbs.
Room Blower: low 500 cfm, high
700 cfm
Exhaust Blower: 326 cfm
Fuel: Whole Kernel Corn, Wheat,
Barley
and/or Wood Pellets
Flue Size: 5 in. Type L, PL, or
High-Temp Metal Flex Vent Pipe
BTU Input Range: (Corn) 20,000
to 170,000
Feed Rate: 2 lbs./ hr. low to 18
lbs./hr. maximum
Power Required: 120 Volts, 600
Watts or 4 Amps |
Model 3101 -
Features:
|
|
|
1. |
A
commercial high output
heating system |
|
2. |
Heavy
duty construction |
|
3. |
Truly
Portable - with
pneumatic tires and
folding handles |
|
4. |
Hopper capacity -
standard 150 lbs.,
optional 300 lbs |
|
5. |
Exceptionally large heat
exchanger with built in
cleaning system |
|
6. |
Two
speed room blower |
|
7. |
Two
augers - run one or both |
|
8. |
Wide
range of heat settings
15,000 to 170,000 BTU |
|
9. |
Unique auger feed design
- no jamming |
|
|
|
 |
Model
1101 - Economic
Dimensions: 25" wide X 25" deep
X 32" tall,
Hopper Capacity: 58 lbs
Minimum Clearance:
Side to Wall: 5"
Back to Wall: 2"
Weight: 258 lbs.
Shipping Weight: 286 lbs.
Room Blower: 265 cfm
Exhaust Blower: 216 cfm
Fuel: Whole Kernel Corn, Wheat,
Barley
and/or Wood Pellets
Air Intake Pipe outside
diameter: 2 in. OD
Flue Size: 3 in. Type L or PL
Vent Pipe
BTU Input Range: (Corn) 14,000
to 40,000
Feed Rate: 1.5 lbs./hr. low to
4.4 lbs./hr. maximum
Power Required: 120 Volts, 400
Watts or 3 Amps |
Model 1101 -
Features:
|
1. |
Heavy
duty construction and
economical |
|
2. |
Simple to operate |
|
3. |
Free
standing area heater |
|
4. |
Unique auger feed design
- no jamming |
|
5. |
Dual
Blowers |
|
6. |
Emissions easily vented
outdoors - simply go
though the wall, no
vertical rise required
.Many built in features
. |
|
|
back to top |
|
|
 |
Model 2004 - Free
Standing Elegance
Dimensions: 27" wide X 25-3/4"
deep X 31-1/4" tall,
Hopper Capacity: 70 lbs
Minimum Clearance:
Side to Wall: 6"
Back to Wall: 2"
Weight: 248 lbs.
Shipping Weight: 289 lbs.
Room Blower: 265 cfm
Exhaust Blower: 216 cfm
Fuel: Whole Kernel Corn, Wheat,
Barley
and/or Wood Pellets
Air Intake Pipe outside
diameter: 2 in. OD
Flue Size: 3 in. Type L or PL
Vent Pipe
BTU Input Range: (Corn) 14,000
to 40,000
Feed Rate: 1.5 lbs./hr. low to
4.4 lbs./hr. maximum
Power Required: 120 Volts, 400
Watts or 3 Amps |
Model 2004 -
Features:
|
1. |
Smooth modern lines with
a bay window elegance |
|
2. |
Large
hopper capacity |
|
3. |
Variable speed room
blower |
|
4. |
Positive venting exhaust
blower |
|
5. |
Unique fire box design -
resulting in super
heating |
|
6. |
Exceptional heat
recovery through large
heat exchangers with
Built in cleaning system |
|
7. |
Unique auger feed design
- no jamming |
|
8. |
Many
built in features |
|
|
| |
Thermostat Control |
|
Hopper Extension
(Model 1201 only) |
| |
Gold Plated Door |
|
300 lb. Hopper
(Model 3101 only) |
| |
Brass Trim |
|
Pedestal Base
(Models 1101 or
1201) |
|
|
|